Select Page

RMC3-BS | SS Series DC

The RMC3-BS series electric wiper is designed for the wiper installed on SS series (SS3, SS4, SS4B, SS4G, SS6B, SS7C, SS7D, SS7E, SS8) locomotives. This wiper is designed in various specifications according to the requirements of each locomotive interface and brushing area. The system includes: electric wiper host, wiper brush rod, boneless brush blade, control device (wiper host and control box are installed separately), etc. The new locomotive control box has a water spray function, and the technical transformation and overhaul products do not have a water spray function. The electric wiper also has a manual reset function. When the circuit cannot be reset or the transmission mechanism fails, the handle should be loosened counterclockwise by 8-10mm, so that the handle can swing the brush rod, and the brush rod and brush blade can return to the initial position.

Advantages of RailMac Wiper

RailMac is a company focused on the railway industry, providing tailor-made wiper solutions to meet the needs of a wide range of vehicles and machinery used in the railway environment. We offer a variety of wiper product lines including high-speed EMUs, locomotives, urban rail transit, etc., to meet the needs of different customers. RailMac offers a one-stop service covering the entire range of wipers under the Lince and Huanji brands, with different options depending on your budget. Its products cover high-speed EMUs, Harmony series AC locomotives, electric internal combustion DC locomotives, urban metro vehicles, air trams and other fields, and provide different voltage levels of electric wipers, including DC110V, DC74V, DC24V, and pneumatic electronic wipers driven by compressed air and controlled by voltage regulation. RailMac has independent intellectual property rights of CRH3 type EMU wiper, which is the first high-speed vehicle wiper product for high-speed trains in China, has completed loading and application evaluation, and obtained relevant qualifications. At present, CRH380 Harmony series, CR400BF/CR300BF Fuxing series EMU wiper products have achieved batch loading. The company provides a 3-year product warranty period and fulfills the promise of “free warranty” during the warranty period. RailMac’s products have been exported to Kazakhstan, Pakistan, Thailand, Sudan, Portugal and other overseas countries, and have been widely used by 18 railway bureaus of China National Railway Group, demonstrating its professional ability in the field of railway accessories and comprehensive satisfaction of customer needs.

Technical Specifications

Product Model:
RMC3-BS
Product Type: Electric Wiper
Rated Voltage:DC 110V
Service Life: 500,000 times
Service Temperature:-40°C~+70°C
Packing Size(L * W * H):N/A
Wet Weight:N/A
Lead Time:15 - 30 Working Days
Payment Terms:T/T ,L/C

coming soon

coming soon

Product Model

Applicable Vehicle Model

Product Type

Control Voltage

Working Environment

Wiper Lifespan

RMC3-DB2/3CR300BF, CR400BF High-Speed TrainsElectric Wiper for High-Speed Trains Operating Voltage: DC 77~137.5V, Rated Voltage: 110VTemperature: -40°C~+70°C, Relative Humidity: ≤96% (at room temperature)Wiper 2×10^6 times, Blade 5×10^5 times
RMC3-FD3CRH3C/380B/380BL High-Speed TrainsPneumatic Wiper for High-Speed TrainsOperating Voltage: DC 77~137.5V,Rated Voltage:10VTemperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)≥ 500,000 times
RMC3-FD1160 km/h Concentrated Power High-Speed TrainsPneumatic Wiper for High-Speed TrainsRated Voltage: DC24VTemperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)≥ 500,000 times
RMC3-AH1HXD1/HXD1B/HXD1C/HXD1D LocomotivesElectric Wiper for LocomotivesOperating Voltage: DC 77~137.5V, Rated Voltage: DC 110VTemperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)≥ 500,000 times
RMC3-AH3-1HXD3C/HXD3D locomotive Electric Wiper for LocomotivesOperating Voltage: DC 77~137.5V
Rated Voltage: DC 110V
Temperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)500,000 times
RMC3-AH5 HXN5 Locomotive
HXN5B Locomotive
 Electric Wiper for LocomotivesOperating Voltage: DC 52~93V
Rated Voltage: DC 74V
Temperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)500,000 times
RMC3-BSSS Series DC Locomotive Electric Wiper for LocomotivesOperating Voltage: DC 77~137.5V
Rated Voltage: DC 110V
Temperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)500,000 times
RMC3-AFDF Series Diesel Locomotives. Electric Wiper for LocomotivesOperating Voltage: DC 77~137.5V
Rated Voltage: DC 110V
Temperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)500,000 times
RMC3-C1H1HXD1 Locomotive Pneumatic Wiper for LocomotivesRated Voltage: DC 24VTemperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)500,000 times
RMSW-75HXD1, HXD1B, Kazakhstan Locomotive, Uzbekistan Locomotive, Iran Locomotive
HXD1D, HXD1B, Zhuzhou Locomotive 200 km/h Passenger
 Pneumatic Wiper for LocomotivesRated Voltage: DC 24VTemperature:-25℃ ~ +70℃ Storage environment temperature -40℃ ~ +70℃ Maximum relative humidity ≤95%≥10 million times
RMSW-75BHXD2、HXD2B Pneumatic Wiper for LocomotivesRated Voltage: DC 24VTemperature:-25℃ ~ +70℃ Storage environment temperature -40℃ ~ +70℃ Maximum relative humidity ≤95%≥10 million times
T3Shanxi (Shaoshan) Series Electric Locomotives Pneumatic Wiper for LocomotivesRated Voltage: DC 24VTemperature:-25℃ ~ +70℃ Storage environment temperature -40℃ ~ +70℃ Maximum relative humidity ≤95%≥10 million times
RMC3-AH3-5/3Beijing Subway Line 3/11/12 ProjectElectric Wiper for Urban Rail Transit VehiclesOperating Voltage: DC 77~137.5V
Rated Voltage: DC 110V
The temperature range is from -40℃ to +70℃, and the relative humidity is ≤90% (at normal temperature).500,000 times
RMSW-1HXD1CElectric Wiper for Urban Rail Transit VehiclesRated Voltage: DC 110VThe maximum relative humidity is ≤95%. The operating environment temperature range is from -25℃ to +70℃, and the storage environment temperature range is from -40℃ to +7℃.≥2 million times
RMSW-2 Beijing, Kunming, Suzhou, Changsha, Singapore Subway Engineering Maintenance VehicleElectric Wiper for Urban Rail Transit VehiclesRated Voltage: DC 110VThe maximum relative humidity is ≤95%. The operating environment temperature range is from -25℃ to +70℃, and the storage environment temperature range is from -40℃ to +7℃.≥2 million times
RMC3BShenzhen Line 5, Guangzhou Line 3, Guangzhou Line 128, Shanghai Line 11, Shanghai Line 16, Kunming Line 1, Wuhan Line 2, Wuhan Line 4, Zhengzhou Line 1, Ningbo Line 1, Wuxi Line 1, Changsha Line 2Electric Wiper for Urban Rail Transit VehiclesRated Voltage: DC 110VThe maximum relative humidity is ≤95%. The operating environment temperature range is from -25℃ to +70℃, and the storage environment temperature range is from -40℃ to +7℃.≥2 million times
DDG0932 Engineering Vehicle, Welding Rail VehicleElectric Wiper for Urban Rail Transit VehiclesRated Voltage: DC 110VThe maximum relative humidity is ≤95%. The operating environment temperature range is from -25℃ to +70℃, and the storage environment temperature range is from -40℃ to +7℃.≥2 million times
RMC3-AH3-3 HXD3 LocomotivesElectric Wiper for HXD3 LocomotivesRated Voltage: DC 110VTemperature: -40°C~+70°C, Relative Humidity: ≤95% (at room temperature)500,000 times
------END------

RMC3-BS Wiper Product configuration information

Electric Wiper Motor Available in various specs for SS series locomotives (e.g., SS3, SS4, SS4B, SS4G, SS6B, SS7C, SS7D, SS7E, SS8, etc.)
Wiper Arm HJSG-Z/540
Wiper BladeHJSP-W/450mm
Control UnitSeparate wiper motor and control box installation. New locomotives have a spray function; reformed and overhauled vehicles do not.
Manual ResetAllows manual reset in case of circuit failure or transmission mechanism issues.
------END------

RMC3-BS Wiper Various data

Wiping FrequencyHigh speed ≥35 times/min, low speed ≤20 times/min, intermittent <20 times/min, the difference between high frequency and low frequency: 10 times/min
Protection FunctionWith over current, short circuit protection and other functions
Manufacturer InformationZhuzhou Huanji Electric Co., LTD
------END------

Note: All Above Data are Just for Reference, All Data Might Change Without Notices or Updates, Please Contact Our Sales Team to Confirm All Details Via WhatsApp or Email.

The picture of Sale Manual showing the accessories and scopes of supply.

Engine Sale Manual

The picture of Installation Drawing showing the accessories and scopes of supply.

Installation Drawing

The picture of Installation Manual showing the accessories and scopes of supply.

Installation Manual

The picture of Operation Manual showing the accessories and scopes of supply.

Operation Manual

The picture of Engine Parts Catalogue showing the accessories and scopes of supply.

Parts Catalogue

The picture of Test Report and Certifcate showing the accessories and scopes of supply.

Report & Certifcate

Global Activity

WhatsApp Online logo

Online Service


Sales Director-Mr.Jasper Lee

Sales Manager-Mrs.Wendy Fu

Spare Parts Sales-Miss. Nora Cao

After-Sales Manager-Ms. Tina Zhang

Merchandiser-Miss. Miss

Contact EMAC Now!

Subscribe To Our Newsletter

Subscribe to get the latest updates from www.railway-wiper.com

Welcome on board, we will keep you updated with latest news and business activities!

Pin It on Pinterest